A metal building sweats because warm, damp air touches cold steel. We stop it by putting insulation tight against the steel. That's usually closed cell spray foam, or a faced fiberglass blanket if the building is still going up. We insulate steel buildings, pole barns and shops in Durham and the counties around it, and the free estimate starts with a visit to your building.
Put insulation tight against the steel so damp air can't reach it. Steel sweats when moist air meets a panel colder than the air. The water beads up and drips onto tools, stock and floors.
It happens in two seasons. On cold nights the roof drops below the air temperature inside. In humid weather, a cooled or closed-up building gets the same problem on its panels. Our area is mixed-humid (Climate Zone 4A on the IECC map used through the 2018 edition, 3A on the 2021 map), so you plan for both seasons here. The R-value guide covers the zone in full.
Loose insulation with gaps behind it doesn't fix this. Damp air finds the gap, reaches the steel and drips behind the insulation where you can't see it. Closed cell foam or a well-sealed faced blanket closes that path.

Yes, for most buildings. Closed cell spray foam bonds straight to the steel and fills the ribs, so there's no cold, damp surface left for condensation to form on. It also seals the seams and screw lines, which is where metal buildings leak air. It works the same way on a pole barn's wood framing and steel siding.
We spray closed cell on the steel itself. We don't use open cell there, because it can hold moisture against the panel. The closed cell and open cell comparison explains the difference.
The steel has to be clean, dry and free of loose rust before we spray, and we check that on the site visit. We set the foam thickness by how you use the building and write it into your estimate.
Spray foam must be covered by an approved thermal barrier, such as 1/2-inch drywall. Limited exceptions apply in attics and crawl spaces entered only for repairs or maintenance. If you work in the shop, plan for that covering. The spray foam page explains how the foam itself goes in.
Faced fiberglass is the budget choice, and it works best while the building is going up. The blanket is laid over the purlins before the roof panels go on. The facing is the vapor barrier, and every seam is taped tight. We install products from makers such as Owens Corning and Johns Manville.
It only works if the facing stays whole. A tear, a loose seam or a gap at the eave lets damp air through to the steel, and the building sweats anyway. Insulation squashed at the purlins also loses much of its value.
On a building that's already standing, fiberglass goes up in a banded or liner system under the roof. That takes more labor and costs you headroom, so foam is often the simpler retrofit. We'll tell you which makes sense for yours. There's more on batts and rolls on the fiberglass insulation page.
We insulate shops, detached garages, storage buildings and barns turned into workspace. The price depends on a few things:
Foam costs more than fiberglass up front. In a building you heat, cool or keep tools in, it also seals the air leaks and stops the dripping. The spray foam cost page shows published price ranges.
Building new with a general contractor, or bidding a commercial job? See commercial and new construction insulation. For a garage attached to your house, see garage insulation.
We're the insulation company to call for steel buildings in Durham, and we work across Chatham, Orange and Person counties too. We come out, measure the building, look at the steel and see where it's dripping. You get the price in writing, with foam or fiberglass explained for your building.
Book the free site visit and tell us what the building is used for.
Yes. Spray foam goes on from the inside, straight onto the roof and wall panels. For fiberglass on a standing building, see the fiberglass section above.
It takes away the wet, cold surface that drives rust from the inside, but it doesn't repair steel that's already rusted. We'll tell you what needs attention first.
Yes. Foam sprayed against the panels deadens the drumming a bare metal roof makes in rain. Faced fiberglass helps too, but foam stuck to the steel does more.
It's a bad plan. Fiberglass left against bare steel with any gap behind it traps damp air at the panel. Choose the system first, and if you plan to foam it, don't hang fiberglass.
Call us and we'll come out to see your building.
Licensed & insured · Free estimates